Roop's Law Assist
Waitlist

GOVERNMENT OF PUNJAB DEPARTMENT OF LOCAL GOVERNMENT (LOCAL GOVERNMENT – I BRANCH)

6001bb26b666c34941eedd02f08994d503fc0a39 · 1994 · Punjab

Download PDFParent ActBack to Subordinates
Parent: The Punjab-Municipal-Corporation-Law-Extension-to-Chandigarh-Act-1994 (45def804246177932c8d9e262d2521623226606a)

Text

GOVERNMENT OF PUNJAB DEPARTMENT OF LOCAL GOVERNMENT (LOCAL GOVERNMENT – I BRANCH) NOTIFICATON No: 9/12/11-4LG1/712 Dated Chandigarh the 7.3.2011 The enclosed Bye-Laws namely the "Municipal Corporation Jalandhar Building Bye-Laws, 2010" made by the Municipal Corporation Jalandhar under Section 258, 398 and 399 of the Punjab Municipal Corporation Act, 1976 and adopted by the Municipal Corporation Jalandhar vide Resolution No. 1065 dated 14 th October, 2010, having been confirmed by the Governor of Punjab as required under Section 401 of the said Act and all other powers enabling him in this behalf are published for general information. These Bye-Laws shall come into force with immediate effect. CHAPTER – I TITLE AND COMMENCEMENT These Bye-Laws may be called the Municipal Corporation, Jalandhar, Building Bye-Laws, 2010. These shall come into force on such date, as the Government may by notification, appoint. These Bye-Laws shall apply to the Municipal area or to such other areas, as the State Government may extend by notification in the official gazette. (4) CHAPTER – II DEFINITIONS NOTE: Words and expressions not defined in this bye – laws shall have the same meaning or the senses as are contained in the Punjab Municipal Corporation Act, 1976. CHAPTER – III PROCEDURE FOR SUBMISSION OF BUILDING APPLICATION AND OCCUPATION. 3.5 NOTICE OF BUILDING APPLICATION: Every person intending to erect or re – erect any building shall give notice of such intention in writing in Form "A" appended to these bye-laws along with ownership documents, four sets of Ferro Prints and two prints on tracing cloth / tracing film showing location plan, site plan, and building plans to the Municipal Corporation and shall at the same time submit: (a) A location plan and a site plan of the land on which

Rule TOC

3 · 5 NOTICE OF BUILDING APPLICATION:
3 · 6 Tax on building application:
3 · 7 Location Plan:
3 · 8 Site Plan:
3 · 9 Building Plan:
3 · 9.1 Building Plans for Multi storied / Special Buildings:
3 · 10 SCRUTINY AND APPROVAL OF BUILDING PLANS
3 · 11 Notice of commencement of work:
3 · 12 PERMISSION TO OCCUPY:
3 · 13 Notice of Completion:
3 · 14 MONITORING OF EXECUTION OF WORKS AND ERECTION OF BUILDING AS PER SANCTIONED PLAN AND APPROVAL OF REVISED PLAN WHEREVER REQUIRED:
3 · 15 COMPOUNDING OF DEVIATIONS FROM THE SANTIONED PLAN :
4 · 1 The proportion up to which a site may be covered with building including ancillary building along with F.A.R. control shall be in accordance with the following slabs, the remaining portion being left open in the form of minimum front set back, and open spaces around the building and space at rear, sides or internal courtyard:
4 · 2 GROUP HOUSING, MULTI-STOREYED BUILDING & APARTMENTS
4 · 3 COMMERCIAL:
4 · 3.1 Site coverage, Parking, Height and F.A.R.:
4 · 3.2 Basement:
4 · 3.3 Staircase:
4 · 4 INDUSTRIAL: Coverage, F.A.R., Height etc.
4 · 4(a) Set back lines, ground coverage and height of industrial buildings in the government approved schemes/industrial focal points transferred to the local bodies shall be a per approved zoning plans/schedule of clauses.
4 · 4(b) in the non-scheme industrial land use zones ground coverage, F.A.R. and height shall be regulated in accordance with the schedule- II and other components shall be regulated as per the provisions of the factories Act, 1948 and the rules made thereunder.
4 · 5 INSTITUTIONAL AND OTHER PUBLIC BUILDINGS:
4 · 6 HEIGHT OF BUILDINGS AND SET BACK:
4 · 7 PROVISION OF BASEMENT IN BUILDINGS:
4 · 8 PROJECTION:
4 · 9 PROVISION OF LIFTS IN BUILDING:
4 · 10 In case of public buildings provisions contained in "The persons with Disability Equal Opportunities Protection of Rights and full Participation Act, 1995", so far as this relates to planning, designing and construction of public buildings and guidelines and space standards for Barrier Free Environment for Disabled and Elderly Persons proposed under this act by CPWD, Ministry of Urban Affairs and Employment India 1998 or as revised from time to time shall be made.
5 · 1 Fire protection: All requirements of fire protection through classification of buildings based on occupancy, type of construction, and other requirements shall be in accordance with the IS-1642/1960 Code of practice for safety of building (General); material and details of construction, and other relevant provisions of the National Building Code with latest amendments.
5 · 2 Electrical Installations: The electrical installations in the building shall be carried out in conformity with the requirements of the Indian Electricity Act, 1910 and the Electricity Rules 1956 as amended from time to time .
5 · 3 Structural design: The structural designs of all the buildings shall be in accordance with the relevant provisions of the B.I.S. code and shall be certified by a recognized Structural Engineer and shall be submitted along with structural safety certificate for buildings having more than 3 storied structure and for buildings up to 3 storeys only a structure safety certificate shall be submitted.
5 · 4 Plinth Level: The plinth level shall not be less than 1'-6" or as may be specified by the competent authority from time to time.
5 · 5 Building Material: The building material to be used for construction of every building shall conform to the material and specifications as are specified in the Punjab Public Works department specifications as amended from time to time.
5 · 6 Efficient Use of Energy:
1 · Industries where hot water is required for processing;
2 · Hospitals & nursing Homes including Government Hospitals;
3 · Hotels, Motels & Banquet Halls;
4 · Group Housing;
5 · Residential Buildings built on a plot of size 500 square yards & above;
6 · All Government Buildings, Residential schools, Educational Colleges, Hostels, Technical / Vocational Education Institutes, District Institutes of Education & Training, Tourism Complexes & Universities etc
6A · (I) The water conservation:For effective conservation of rain water, application for permission to construct
6A · (II) Separation of bath and washbasin water and reuse:Notwithstanding anything contained in these rules, every building shall be provided with separate pipelines, one for collecting wastewater from bath and washbasin and the other for connecting the toilets. The waster water from the toilets alone shall be connected to the street sewer. The wastewater from the bath and washbasin shall be disposed off as here under:-
6A · (iii) Provision of rain water harvesting structures in existing buildings:Notwithstanding any thing confirmed in this rules, Rainwater harvesting structures as detailed in rules 3 shall be provided in all the existing buildings, with incentives to the owners in a policy to be decided by the Govt.
7 · 1 The Marriage palace building shall be in accordance with the schedule-III & the relevant provisions contained in chapter II, III, IV, V, VI and X as far as they are not inconsistent with the provisions made in chapter-VII.
7 · 2 PROVISION OF BASEMENT: Basement may be used for Banquet Hall etc. if it is air-conditioned. It shall have minimum either two staircases for entry and exit or two approach ramps or one staircase and one ramp with additional staircases as per norms of fire safety and number of users. The twin basement may be allowed, if all other conditions regarding structural stability, fire safety, light and ventilation are fulfilled and the lower basement shall be used exclusively for parking.
7 · 3 The premises shall be kept neat & clean and all sanitary components shall provide adequate ventilation, suitable drainage, separate toilets for ladies and gents shall be provided/maintained to the entire satisfaction of Municipal Council and Municipal Council.
7 · 4 Minimum permissible noise level as prescribed by Punjab Pollution Control Board shall be ensured.
7 · 5 No marriage palace shall be allowed directly abutting on the National, State High ways and Major District roads except having access through a service road or where there is possibility or providing a service road so as to ensure safe and free flow of traffic.
7 · 6 Marriage Palaces should be at least 500 square yards. away from schools/colleges/religious places/hospitals.
7 · 7 The use and occupancy of the building/structure approved as marriage palace
7 · 8 In case the terms and conditions of license are not fulfilled including lifting/proper disposal of garbage, fire safety or if any alteration in the building is made without approval, the license shall liable to be cancelled by the authorities as per rules.
7 · 9 Additional provision for the fire safety: -
7 · 10 The provisions contained in "The persons with Disability Equal Opportunities protection of Rights & Full participation Act, 1996", so far as this relates to planning, designing and construction of public buildings, guidelines and space standards for Barrier Free Environment for Disabled & Elderly persons proposed under this Act by CPWD, time to time shall also be compiled with.
8 · 1 The Nursing home/hospital building shall be in accordance with the scheduleIV & the relevant provisions contained in chapter II, III, IV, V, VI & X as far as they are not inconsistent with the provisions made in chapter-VIII.
8 · 2 Provisions of Basement: The double basement may be allowed, if all other conditions for structural stability, fire safety, light and ventilation are fulfilled and one of the basements shall be used exclusively for parking.
8 · 3 PROVISION OF LIFT AND RAMPS: Every building having more than fifteen meters height shall be provided with a minimum of one lift and total number of such lifts shall be calculated on the basis of one lift for every 900 square meter floor area having more than 15 Meters height.
8 · 4 Water storage Tank: Every such building shall have a water storage capacity of 200 liters per bed with an additional storage of 100 liters per bed where laundry facility is provided.
8 · 5 Alternate Power Supply facility: Every such building shall have a provision for an alternate power supply and proper area will be earmarked for installation of a silent generator or any other mode at such place that it will not cause any inconvenience to the patients, public in general and the neighborhood.
8 · 6 The provisions contained in "The persons with Disability Equal Opportunities protection of Rights & Full participation Act, 1996", so far as this relates to planning, designing and construction of public buildings, guidelines and space standards for Barrier Free Environment for Disabled & Elderly persons proposed under this Act by CPWD, Ministry of Urban Affairs & Employment India-1998 or as revised from time to time shall also be compiled with.
8 · 7 Adequate arrangements for disposal of hospital waste have to be made as per the Bio Medical Waste (Management and Handling) Rules, 1998 as amended from time to time along with the instructions/guidelines issued by the Punjab Pollution Control Board from time to time.
9 · 1 The Multiplex building shall be in accordance with the schedule-V & the relevant provisions contained in chapter II, III, IV, V, VI and X as far as they are not inconsistent with the provisions made in chapter-IX.
9 · 2 PROVISIONS OF BASEMENT: The construction of double level basement shall be compulsory for parking and the entire area of the basement shall be used for parking purposes only except the area used for Air-conditioning plant and Lift room which in no case shall exceed 10% of the area. Basement shall be permitted only under the built up area at the ground level.
9 · 3 The provisions contained in "The persons with Disability Equal Opportunities protection of Rights & Full participation Act, 1996", so far as this relates to planning, designing and construction of public buildings, guidelines and space, standards for Barrier Free Environment for Disabled & Elderly persons proposed under this Act by CPWD, Ministry of Urban Affairs & Employment India-1998 or as revised from time to time shall also be compiled with.
2 · Date of issue of (a)permission to occupy _______